Eagle Fire is listed by BM TRADA as certified for Q-Mark Fire Door Installation, Fire Door Maintenance and Fire Stopping Installation. Certification scope, competence evidence and project documentation should be checked against the work being commissioned.

Legal responsibility: Responsible persons should identify the duties that apply to their premises and manage fire-door condition as part of their wider fire-safety arrangements.
Discuss a survey

Our accreditations

Certification
and evidence.

Eagle Fire’s BM TRADA supplier profile records the three Q-Mark schemes below. Buyers should verify the current certificate, certified scope and suitability for the proposed works.

BM TRADA Q-MarkFire Door Installation

Listed as certified on Eagle Fire’s BM TRADA supplier profile.

BM TRADA Q-MarkFire Door Maintenance

Listed as certified on Eagle Fire’s BM TRADA supplier profile.

BM TRADA Q-MarkFire Stopping Installation

Listed as certified on Eagle Fire’s BM TRADA supplier profile.

Verify Eagle Fire on BM TRADA
Fire door inspection

Regulatory framework

Regulatory context
for fire door work.

Fire Safety Act 2021

Amends the Regulatory Reform (Fire Safety) Order 2005 in relation to external walls, flat entrance doors and the structure of relevant multi-occupied residential buildings.

Confirm applicability to the premises.

Building Safety Act 2022

Introduced the building-safety regime for higher-risk buildings in England, including building-safety information commonly described as the golden thread.

Check current Building Safety Regulator guidance.

Fire Safety (England) Regulations 2022

Create specific fire-door and resident-information duties for relevant residential buildings. Regulation 10 includes 3-month communal fire-door checks and 12-month flat entrance door checks using best endeavours for buildings above 11 metres.

Confirm the building is within scope.

Regulatory Reform (Fire Safety) Order 2005

Places duties on the responsible person to take such general fire precautions as are reasonably required to ensure the safety of relevant persons.

Consider with the fire risk assessment.

Approved Document B

Provides statutory guidance on meeting Building Regulations fire-safety requirements in England. The relevant volume and edition should be confirmed for the work.

Use the edition applicable to the project.

BS 8214

A British Standard covering fire door assemblies. The current edition and project-specific requirements should be confirmed before work is specified or undertaken.

Check standard, specification and manufacturer guidance.

The risk of inaction

Fire-door condition
needs active management.

Fire-door defects should be considered in the context of the building’s fire strategy, fire risk assessment and applicable legal duties. Responsible persons should obtain appropriate specialist or legal advice where required.

Building-specific fire-risk assessment findings
The responsible person’s statutory duties
Applicable Regulation 10 requirements
Product evidence and manufacturer instructions
Records of inspection, maintenance and remedial decisions
Appropriate escalation where defects are identified

Protect your position.

An inspection or survey should be agreed against the premises, its access arrangements, fire strategy and the information required by the duty holder.

Project-specific scope
Relevant premises information
Access arrangements
Work requirements

Act now

Get your compliance
position confirmed today.

A fire door inspection or survey should be clearly scoped to the premises, its fire strategy, access arrangements and the information required by the duty holder.

Service proposals are scoped to the requirement

Book a Compliance Survey

Tell us the building, access arrangements and rough door count and we’ll review the survey requirement with you.

Please include the site location, required service and approximate number of doors when you contact us.